Программы

Dphn 142 Official

For further technical data, design-in support, or to request a sample unit, consult the official datasheet (revision 4.2 or later) or contact your local authorized distributor. Last updated: October 2023. Specifications subject to change without notice. Always refer to the manufacturer’s current documentation for the DPHN 142.

| Feature | DPHN 142 | Generic Filter X (Model F-100) | Generic Filter Y (Model EMI-200) | |---------|----------|--------------------------------|----------------------------------| | Filter Stages | Dual | Single | Single | | Insertion Loss @ 10 MHz | 40 dB | 25 dB | 30 dB | | LED Status Indicators | Yes (3 colors) | No | No | | DIN-rail Mounting | Yes (with adapter) | No | Yes | | UL Listing | UL 508 | None | UL only (not 508) | | Maximum Operating Altitude | 5,000m | 2,000m | 3,000m | | Mean Time Between Failures (MTBF) | 500,000 hours | 150,000 hours | 200,000 hours | | Price (USD, 1-9 units) | $42.50 | $29.00 | $38.00 | dphn 142

| Specification | Value/Range | |---------------|--------------| | Rated Voltage | 250V AC / 120V DC | | Rated Current | 10A per line (max 142A aggregated for multi-phase) | | Insulation Resistance | >100 MΩ at 500V DC | | Dielectric Withstand Voltage | 1500V AC for 1 minute | | Insertion Loss (EMI Filtering) | 40 dB minimum @ 10 MHz to 1 GHz | | Leakage Current | <0.5 mA at 250V AC | | Wire Gauge Compatibility | 14 AWG to 22 AWG | | Mounting Torque | 0.5 Nm to 0.6 Nm | For further technical data, design-in support, or to

When selecting your next power entry filter or transient suppressor, remember that the initial savings of a generic component are quickly erased by downtime, troubleshooting hours, and premature equipment failure. By specifying DPHN 142, you invest in operational continuity and peace of mind. | Symptom | Possible Cause | Corrective Action

| Symptom | Possible Cause | Corrective Action | |---------|----------------|--------------------| | No output voltage; all LEDs off | No input power; blown internal fuse | Check upstream breaker; replace DPHN 142 (fuse is non-user-serviceable) | | Red LED steady on | Reversed input polarity | Swap L1 and N (or + and - for DC) | | Amber LED blinking | High leakage current due to moisture or damaged cable | Perform insulation resistance test; dry unit at 50°C for 4 hours | | Equipment resets randomly (intermittent) | Loose ground connection or terminal screw | Re-torque all connections; check PE continuity | | Green LED on but load not working | Broken internal inductor (rare) | Shake unit—if rattling, replace immediately | | Overheating (case >85°C) | Overcurrent beyond 10A per line; poor ventilation | Reduce load or add forced air cooling |

Получать новости
Статистика сайта

Hits
112687160
32857

Hosts
4977438
247

Visitors
109264863
32724
427

Dphn 142 Official

Скачать ZwCAD

ZwCAD 2018 PRO (32/64 Bit. RUS/Eng)




dphn 142

facebook-logo.png v_k_logo.jpg odnoklassniki_logo.jpg mail_ru_logo.jpg tweeter_logo.jpg