Dphn 142 OfficialFor further technical data, design-in support, or to request a sample unit, consult the official datasheet (revision 4.2 or later) or contact your local authorized distributor. Last updated: October 2023. Specifications subject to change without notice. Always refer to the manufacturer’s current documentation for the DPHN 142. | Feature | DPHN 142 | Generic Filter X (Model F-100) | Generic Filter Y (Model EMI-200) | |---------|----------|--------------------------------|----------------------------------| | Filter Stages | Dual | Single | Single | | Insertion Loss @ 10 MHz | 40 dB | 25 dB | 30 dB | | LED Status Indicators | Yes (3 colors) | No | No | | DIN-rail Mounting | Yes (with adapter) | No | Yes | | UL Listing | UL 508 | None | UL only (not 508) | | Maximum Operating Altitude | 5,000m | 2,000m | 3,000m | | Mean Time Between Failures (MTBF) | 500,000 hours | 150,000 hours | 200,000 hours | | Price (USD, 1-9 units) | $42.50 | $29.00 | $38.00 | dphn 142 | Specification | Value/Range | |---------------|--------------| | Rated Voltage | 250V AC / 120V DC | | Rated Current | 10A per line (max 142A aggregated for multi-phase) | | Insulation Resistance | >100 MΩ at 500V DC | | Dielectric Withstand Voltage | 1500V AC for 1 minute | | Insertion Loss (EMI Filtering) | 40 dB minimum @ 10 MHz to 1 GHz | | Leakage Current | <0.5 mA at 250V AC | | Wire Gauge Compatibility | 14 AWG to 22 AWG | | Mounting Torque | 0.5 Nm to 0.6 Nm | For further technical data, design-in support, or to When selecting your next power entry filter or transient suppressor, remember that the initial savings of a generic component are quickly erased by downtime, troubleshooting hours, and premature equipment failure. By specifying DPHN 142, you invest in operational continuity and peace of mind. | Symptom | Possible Cause | Corrective Action | Symptom | Possible Cause | Corrective Action | |---------|----------------|--------------------| | No output voltage; all LEDs off | No input power; blown internal fuse | Check upstream breaker; replace DPHN 142 (fuse is non-user-serviceable) | | Red LED steady on | Reversed input polarity | Swap L1 and N (or + and - for DC) | | Amber LED blinking | High leakage current due to moisture or damaged cable | Perform insulation resistance test; dry unit at 50°C for 4 hours | | Equipment resets randomly (intermittent) | Loose ground connection or terminal screw | Re-torque all connections; check PE continuity | | Green LED on but load not working | Broken internal inductor (rare) | Shake unit—if rattling, replace immediately | | Overheating (case >85°C) | Overcurrent beyond 10A per line; poor ventilation | Reduce load or add forced air cooling | Получать новости
Статистика сайта
Hits
112687160
32857
Hosts
4977438
247
Visitors
109264863
32724
427
|
Dphn 142 Official
Скачать ZwCAD
|
Поиск
Новости
13.04.2026
АВС-4 2026.4 от 13.04.2026 г.
20.03.2026
SANA 2026.3 от 20.03.2026 г.
18.12.2025
АККОРД 2025.1 от 18.12.2025 г.
21.02.2025
ZWCAD 2025
14.02.2025
СРД Средний и текущий ремонт, содержание автодорог
23.01.2025
LIRA-FEM 2025
13.01.2025
АВС-ПИР KZ 2025.1 от 13.01.2025 г. Статьи
|